Table of Contents
Section A: Wiring Diagram ................................. 2 – 3
Section B: Basic Troubleshooting .............................4
Section C: A2-146/A2-153 Troubleshooting ..............5
Section D: A2-214 Troubleshooting .................... 6 – 9
Section E: C653 w/A2-338 Troubleshooting ... 10 – 11
Page 1
TG13G
Hazard De nitions
These terms are used to bring attention to presence of hazards of
various risk levels or to important information concerning product
life.
Indicates presence of hazards that
will or can cause minor personal
injury or property damage.
Indicates special instructions on
installation, operation or mainte-
nance that are important but not
related to personal injury hazards.
CAUTION
NOTICE
C653/C653A and C625 Alternators
Troubleshooting Guide
C.E. Niehoff & Co.
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during
cold-start voltage tests.
Maintenance/Low Maintenance Battery
Immediately after engine starts, system volts are
lower than regulator setpoint, amps are medium.
35 minutes into charge cycle, system volts
increase, amps decrease.
510 minutes into charge cycle, system volts
increase to, or near, regulator setpoint and amps
decrease to a minimum.
Low maintenance battery has same characteristics
with slightly longer recharge times.
Maintenance-free Battery
Immediately after engine starts, system volts are
lower than regulator setpoint, low charging amps.
Once charge cycle begins, low volts and low amps
are still present.
After alternator energizes, voltage will increase
several tenths. Amps will increase gradually, then
quickly, to medium to high amps.
F i n a l l y, v o l t s w i l l i nc r e a s e t o s e t p o i n t a n d a m p s w i l l
decrease.
The time it takes to reach optimum voltage and amper-
age will vary with engine speed, load, and ambient
temperature.
High-cycle Maintenance-free Battery
These batteries respond better than standard mainte-
nance-free. Charge acceptance of these batteries may
display characteristics similar to maintenance batteries.
AGM (Absorbed Glass Mat) Maintenance-free Battery
These dry-cell batteries respond better than standard
maintenance-free. If battery state of charge drops to
75% or less, batteries should be recharged to 95% or
higher separately from the engine’s charging system to
avoid damaging charging system components and to
provide best overall performance. Charge acceptance of
these batteries may display
characteristics similar to
maintenance batteries.
NOTICE
Battery Charge Volt and Amp Values
Volt and amp levels fluctuate depending on the battery state
of charge. If batteries are in a state of dischargeas after
extended cranking time to start the enginesystem volts
will measure lower than the regulator setpoint after the
engine is restarted and system amps will measure higher.
This is a normal condition for the charging system; the
greater the battery discharge level, the lower the system
volts and the higher the system amps. The volt and amp
readings will change as batteries recover and become fully
charged: system volts will increase to regulator setpoint
and system amps will decrease to low level (depending on
other loads).
Low Amps: Minimum or lowest charging system amp
value required to maintain battery state of charge,
obtained when testing the charging system with a fully
charged battery and no other loads applied. This value
will vary with battery type.
Medium Amps: System amps value which can cause
the battery temperature to rise above adequate charging
temperature within 4-8 hours of charge time. To pre-
vent battery damage, the charge amps should be
reduced when battery temperature rises. Check battery
manufacturer’s recommendations for proper charge
amp rates.
High Amps: System amps value which can cause
the battery temperature to rise above adequate charging
temperature within 2-3 hours of charge time. To pre-
vent battery damage, the charge amps should be
reduced when battery temperature rises. Check battery
manufacturer’s recommendations for proper charge
amp rates.
Battery Voltage: Steady-state voltage value as mea-
sured with battery in open circuit with no battery load.
This value relates to battery state of charge.
Charge Voltage: Voltage value obtained when the
charging system is operating. This value will be higher
than battery voltage and must never exceed the regula-
tor voltage setpoint.
B+ Voltage: Voltage value obtained when measuring
voltage at battery positive terminal or alternator B+
terminal.
Surface Charge: Higher than normal battery voltage
occurring when the battery is disconnected from
battery charger. The surface charge must be removed
to determine true battery voltage and state of charge.
Significant Magnetism: Change in strength or inten-
sity of a magnetic field present in alternator rotor shaft
when the field coil is energized. The magnetic field
strength when the field coil is energized should feel
stronger than when the field is not energized.
Voltage Droop or Sag: Normal condition occurring
when the load demand on alternator is greater than
rated alternator output at given rotor shaft RPM.
Seitenansicht 0
1 2 3 4 5 6 ... 10 11

Inhaltsverzeichnis

Seite 1 - C.E. Niehoff & Co

Table of ContentsSection A: Wiring Diagram ... 2 – 3 Section B: Basic Troubleshooting ...4 Sec

Seite 2 - Section A: Wiring Diagrams

Page 10TG13GSection E: C653 w/A2-338 Advanced TroubleshootingA2-338 RegulatorDescription and OperationA2-338 regulator is attached directly to the out

Seite 3

Page 11TG13GSelf-energized alternator may have lost magnetism. Touch steel tool to shaft to detect any magnetism. Is shaft magnetized?Momentarily (1 s

Seite 4

Page 2TG13GSection A: Wiring DiagramsB– terminalstudP terminal IGN terminalFigure 1 — C625 Alternator Terminals B+ terminal studD+ terminalFigure

Seite 5

Page 3TG13GFigure 4 — C653/C653A Alternators with A2-146 or A2-153 or A2-338 RegulatorFigure 5 — C653/C653A and C625 Alternators with A2-214 Regulator

Seite 6 - A2-214 Regulator

Page 4TG13GSYMPTOM ACTIONTABLE 1 – System ConditionsCheck: loose drive belt; low battery state of charge.Check: current load on system is g

Seite 7 - Quick Diagnostic

Page 5TG13GSection C: A2-146/A2-153 Advanced TroubleshootingA2-146/A2-153 REGULATOR – THIS PAGE ONLY Self-energized alternator may have lost magnetism

Seite 8

Page 6TG13GA2-214 Regulator DESCRIPTION AND OPERATIONA2-214 regulator is either attached directly to the outside of alternator or remote-mounted.Main

Seite 9 -

Page 7TG13GChart 2 – No Alternator Output – Quick DiagnosticFigure 7 – Alternator-to-Regulator Harness Plug PIN CONNECTIONS Pin A

Seite 10 - Troubleshooting

Page 8TG13GChart 3 – No Alternator Output – Test Charging CircuitSTATIC TEST – ENGINE OFF, BATTERY SWITCH ON, KEY ON PIN CONNECTIONS P

Seite 11

Page 9TG13GSection D: A2-214 Advanced Troubleshooting (CONT’D) Repair vehicle circuit to IGN terminal. Vehicle charging circuit test is