Page 1
TG0018A
Table of Contents
Section 1: Wiring Diagram...................................... 2
Section 2: Basic Troubleshooting ........................... 3
Section 3: Advanced Troubleshooting..................4–5
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during cold start voltage tests.
Maintenance/low maintenance battery:
Immediately after engine starts, system volts
are lower than regulator setpoint with medium
amps.
3-5 minutes into charge cycle, higher system
volts and reduced amps.
5-10 minutes into charge cycle, system volts
are at, or nearly at, regulator setpoint, and
amps are reduced to a minimum.
Low maintenance battery has same charac-
teristics with slightly longer recharge times.
Maintenance-free battery:
Immediately after engine start, system volts
are lower than regulator setpoint with low
charging amps.
15-30 minutes into charge cycle, still low volts
and low amps.
15-30 minutes into charge cycle, volts increase
several tenths. Amps increase gradually, then
quickly to medium to high amps.
20-35 minutes into charge cycle, volts increase
to setpoint and amps decrease.
High-cycle maintenance-free battery:
These batteries respond better than standard
maintenance-free. Charge acceptance of these
batteries may display characteristics similar to
maintenance batteries.
NOTICE
Hazard Definitions
These terms are used to bring attention to presence of hazards
of various risk levels or to important information concerning
product life.
Indicates presence of hazards
that will or can cause minor
personal injury or property damage if ignored.
Indicates special instructions
on installation, operation or
maintenance that are important but not related to
personal injury hazards.
CAUTION
NOTICE
N1506 Series Troubleshooting Guide
for N1506-1 Alternators
Charge Volt and Amp Values
The volt and amp levels are a function of the battery
state of charge. If batteries are in a state of discharge,
as after extended cranking time to start the engine, the
system volts, when measured after the engine is started
will be lower than the regulator setpoint and the system
amps will be high. This is a normal condition for the
charging system. The measured values of system volts
and amps will depend on the level of battery discharge.
In other words, the greater the battery discharge level,
the lower the system volts and higher the system amps
will be. The volt and amp readings will change, system
volts reading will increase up to regulator setpoint and
the system amps will decrease to low level (depending
on other loads) as the batteries recover and become fully
charged.
Low Amps: A minimum or lowest charging system
amp value required to maintain battery state of
charge, obtained when testing the charging system
with a fully charged battery and no other loads
applied. This value will vary with battery type.
Medium Amps: A system amps value which can
cause the battery temperature to rise above the
adequate charging temperature within 4-8 hours of
charge time. To prevent battery damage, the charge
amps should be reduced when battery temperature
rises. Check battery manufacturer’s recommenda-
tions for proper rates of charge amps.
High Amps: A system amps value which can cause
the battery temperature to rise above adequate
charging temperature within 2-3 hours. To prevent
battery damage the charge amps should be reduced
when the battery temperature rises. Check battery
manufacturer’s recommendations for proper rates
of charge amps.
Battery Voltage: Steady-state voltage value as
measured with battery in open circuit with no
battery load. This value relates to battery state of
charge.
Charge Voltage: A voltage value obtained when the
charging system is operating. This value will be
higher than battery voltage and must never exceed
the regulator voltage setpoint.
B+ Voltage: A voltage value obtained when measur-
ing voltage at battery positive terminal or alternator
B+ terminal.
Surface Charge: A higher than normal battery
voltage occurring when the battery is removed from
a battery charger. The surface charge must be
removed to determine true battery voltage and state
of charge.
Significant Magnetism: A change in the strength or
intensity of a magnetic field present in the alternator
rotor shaft when the field coil is energized. The
magnetic field strength when the field coil is ener-
gized should feel stronger than when the field is not
energized.
Voltage Droop or Sag: A normal condition which
occurs when the load demand on the alternator is
greater than rated alternator output at given rotor
shaft RPM.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1

Page 1TG0018ATable of ContentsSection 1: Wiring Diagram... 2Section 2: Basic Troubleshooting ...

Seite 2 - Section 1: Wiring Diagram

Page 2TG0018ASection 1: Wiring DiagramCEN N1506-1 Dual Voltage Alternator Description and OperationN1506-1 100 A (28 /14 V) dual voltage alternator is

Seite 3 - TABLE 1 – System Conditions

Page 3TG0018AD. Basic TroubleshootingBefore troubleshooting,verify correct wiring ofalternator to vehicle.See Figure 1 for correctconnections to alter

Seite 4 - PIN CONNECTIONS

Page 4TG0018ASection 3: Advanced TroubleshootingWith engine off and key on, is battery voltage present at BOTH alternator 28 V and 14 V B+ terminals?Y

Seite 5

Page 5TG0018AYesNoWith engine off, is battery voltage present at alternator 14 V B+ terminal?Chart 2 – No 14 V Alternator Output – Test CircuitYesNoCo

Seite 6

Page 6TG0018ANotes

Seite 7

Page 7TG0018ANotes

Seite 8

Page 8TG0018AIf you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Distri

Kommentare zu diesen Handbüchern

Keine Kommentare